- Single-leaf door 1681x3534mm
- Double doors 1600x3534mm
Maximum height of the structure with a top transom: 4692mm
Fire resistance: EI230
Thermal transmittance: Ud >0,9 W/m2*K
Water resistance: 6A
Wind load resistance: C2
Smoke tightness: Sa,S200 *
Additional information:
Pressed profiles made of EN AW-6060 alloy according to PN-EN 573-3:2009. Dimensional and shape tolerances are in accordance with the PN-EN 12020-2:2001 standard. Rectangular connections of the sections are obtained by cutting the profile at an angle of 45® and inserting two corners into the profile chambers, which can be pinned or crimped. Transverse connections are made using connectors that must be pinned. The central chamber of the profile is filled with a fire-retardant insert with low thermal conductivity λ.
FIRE RESISTANCE
WATERPROOF
SMOKE TIGHTNESS
THERMAL TRANSMISSION
RESISTANCE TO WIND LOAD
Certificate of Constancy of Performance 1488-CPR-1072/W
Classification report 03515.2/20/Z00NZE/B
* Classification report 03515.6/20/Z00NZE/B
Aluminum system intended for interior doors where fire protection class is required, with the possibility of expanding the development with double-sided sidelights and an upper transom. It is possible to make single-leaf and double-leaf doors. The depth of the frame and sash profiles is 84mm.
It is possible to use a wide range of fillings, from single glass through single- and double-chamber glass to opaque panel fillings. When using the appropriate range, it is possible to obtain a smoke tightness class.