Facilitate access

SYSTEM AC-84 EI60

internal fire doors
Maximum dimensions:

Maximum leaf dimensions:

  1. Single-leaf door 1611x3387mm
  2. Double doors 1333x2945mm

Maximum height of the structure with a top transom: 4080mm

parameters

Fire resistance: EI260

Mechanical durability: 500 thousand cycles *

Air permeability: Class 3

Impact resistance: Class 3

Smoke tightness: Sa,S200 **

Details:

Pressed profiles made of EN AW-6060 alloy according to PN-EN 573-3:2009. Dimensional and shape tolerances are in accordance with the PN-EN 12020-2:2001 standard. Rectangular connections of the profiles are obtained by cutting the profile at an angle of 45® and inserting two corners into the profile chambers, which can be pinned or crimped. Transverse connections are made using connectors that must be pinned. All three chambers of the profile are filled with a fire-retardant insert with low thermal conductivity λ.

EI 60

FIRE RESISTANCE

CLASS 3

AIR PERMEABILITY

CLASS 3

IMPACT RESISTANCE

500 thousand cycles *

MECHANICAL DURABILITY

Sa,S200 **

SMOKE TIGHTNESS

** Classification report 03515.6/20/Z00NZE/B
*for doors equipped with 5 hinges

Aluminum system intended for interior doors where fire protection class is required, with the possibility of expanding the development with double-sided sidelights and an upper transom. It is possible to make single-leaf and double-leaf doors.

The depth of the frame and sash profiles is 84mm. It is possible to use a wide range of fillings, from single glass through single- and double-chamber glass to opaque panel fillings. When using the appropriate range, it is possible to obtain a smoke tightness class.